GT-AJY-01-ZY
1. Integrate methane detector, temperature detector, and flammable volatile matter detector to monitor the environmental data in the cabin in real time all day long.
2. It has alarm forecasting and real-time fault (open circuit/short circuit/detector failure, etc.) self-checking functions, which can promptly detect abnormal temperature and combustible gas data in the compartment and quickly alarm.
3. Advanced integrated computer control, with functions such as data storage and real-time uploading and sharing of data, to facilitate subsequent investigation of fire and alarm causes.
4. Through CAN protocol, the line speed is simple, the communication is stable and reliable, and the detector can be expanded flexibly.
5. The system comes with a Chinese display screen that displays system status and related fault information in real time. The system can freely adjust specific parameters according to the personalized requirements of the bus.
| Part name | parameters | |
| Security inspection device on board the vehicle | Model | GT-AJY-01-ZY |
| Working voltage, rated power consumption | 18-32V | |
| Size | 121*86*35mm | |
| Detector communication protocol | CAN bus protocol, rate 250K, standard mode | |
| Detection type | Temperature, methane, flammable volatiles | |
| Measuring range | Methane 0-100%LEL | |
| Operating temperature range (℃) | -20℃~+65℃ | |
| Working humidity | ≤95% | |
| Product expiry date | 8 years | |
| Monitoring and alarm device | Model | GT-XSQ2.8-ZY |
| Working voltage, rated power consumption | 18-32V | |
| Size | 104*64*35mm | |
| screen size | 2.8 inches | |
| Detector communication protocol | CAN bus protocol, rate 250K, standard mode | |
| Alarm volume | >80dB | |
| Operating temperature range (℃) | -20℃~+65℃ | |
| Working humidity | ≤95% | |
| Product expiry date | 8 years | |
| Monitoring device | Model | GT-JC-01-ZY |
| Working voltage, rated power consumption | 18-32V | |
| Size | 121*86*35mm | |
| Detector communication protocol | CAN bus protocol, rate 250K, standard mode | |
| Detection type | Temperature, methane, flammable volatiles | |
| Measuring range | Methane 0-100%LEL | |
| Operating temperature range (℃) | -20℃~+65℃ | |
| Working humidity | ≤95% | |
| Product expiry date | 8 years | |
| Working voltage, rated power consumption | 18-32V | |
| Size | 313*58*76mm | |
| Operating temperature range (℃) | -20℃~+65℃ | |
| Working humidity | ≤95% | |
| Product expiry date | 8 years | |