FFX-ACD0.1/0.15-ZY02
FFX-ACD0.1-ZY02 and FFX-ACD0.15-ZY02 suspended dry powder fire extinguishing devices are non pressure storage slow-release single jet nozzle type vehicle fire extinguishing devices, consisting of containers, ultra-fine dry powder, gas producing blocks, starting triggers (thermal triggers, electric triggers), temperature control switches, emergency start alarm button boxes, and other components.
The device is equipped with two optional startup modes:
1. When the ambient temperature reaches 170 ℃ or an open flame appears, the thermal initiator is triggered and ignited, achieving automatic activation of the fire extinguishing device;
2. Press the emergency start alarm button to manually activate the fire extinguishing device.
| Specifications and models | FFX-ACD0.1-ZY | FFX-ACD0.15-ZY |
| Fire extinguishing agent type | ABC ultrafine dry powder | ABC ultrafine dry powder |
| Fire extinguishing agent mass (g) | 100+5 | 150+7.5 |
| Fire extinguishing ability | Special for engine compartment | Special for engine compartment |
| Thermal initiator starting temperature (℃) | 170±10 | 170±10 |
| Start mode | Electric control, temperature control | Electric control, temperature control |
| Injection time(s) | ≤5 | ≤5 |
| Operating ambient temperature (℃) | -40~+90 | -40~+90 |
| electrical initiator resistor | 2.4Ω~3.3Ω | 2.4Ω~3.3Ω |
| Safety current (mA) | ≤150 | ≤150 |
| Starting current (mA) | ≥380 | ≥380 |
| Use voltage (V) | DC 9~24 | DC 9~24 |
| Weight(g) | 660±20 | 830±20 |
| Overall dimensions (mm) | 70*199 | 70*248.5 |
| reaction force | 1.8KN | 1.8KN |
| Action time | 14ms | 14ms |
1. Large nozzle: The nozzle is large and the spray speed is fast. The dry powder quickly fills the protected area and extinguishes the fire quickly;
2. Dual start mode: it can be started manually through electronic control or automatically through a thermal initiator;
3. Line self-test: When the control line is short-circuited or broken, the alarm indicator light on the button box will light up;
4. Storage under normal pressure, safe to use and easy to install.